H3TRB/HTRB Testplätze
![](/fileadmin/_processed_/6/a/csm_HTRB-Pruefstand1_6de3cc62d0.jpg)
![](/fileadmin/_processed_/e/3/csm_HTRB-Pruefstand2_29eff7b412.jpg)
![](/fileadmin/_processed_/0/5/csm_HTRB-Pruefstand3_1f3c65156b.jpg)
![](/fileadmin/_processed_/6/5/csm_HTRB-Pruefstand4_e3e2e7458d.png)
4 Tester for High Power Silicon Devices
- 180l climate chambers
- 16 channel high voltage DAQ
- Voltages ≤ 10kV
- Currents ≥ 10µA
- Test variations:
- Climate- and voltage- cycling
- Condensation tests
- 2 test voltages in 1 chamber
3 Tester for SiC- and GaN – Devices
- 50 – 180l climate chambers
- Temperature: -70 to 180°C
- Rel. Humidity: 10 to 95%
- 16 – 32 Channels
- Voltages ≤ 5kV
- Currents ≥ 100nA