Instrument Database
Other
HiPE-LAB

General information
-
Investigation area
-
TechniquesPower electronics testing
-
ManufacturerIALB
-
Fabrication year2021
-
Measured quantityTemperature, relative humidity, airflow, current, voltage, power
-
Main applicationMultimodal lifetime tests (under climate and electrical conditions, destructive and non destructive) on power electronics.
-
In-situ, real-time compatibleYes
Instrument specification
-
Technical aspects
Electrical load system: Power range up to 10 MVA with a voltage range from 0 to 1,000 V AC, currents up to 9,000 A AC and a frequency range from 0 to 70 Hz.
Climate room: Temperature range from -40 °C to +120 °C, 10 % to 95 % relative humidity at +10 °C to +95 °C, Test room (l x w x h) 7.5m x 5.3 m x 4.3 m, Cooling water supply temperature for the DUT from +16 °C to +60 °C.
Measurement system: Up to 72 channels with 2 MSamples/s for voltages and currents and up to 64 channels with 20 kSamples/s temperature, relative humidty and airflow. Fully automated tests due to an flexible and extendable controll system. -
In-situ capabilitiesTemperature range from -40 °C to +120 °C; relative humidity 10 % to 95 % at +10 °C to +95 °C; Cooling water supply temperature for the DUT from +16 °C to +60 °C.
Contact
-
Application scientistWilfried Holzke
Fachbereich 1 , IALB
FB1, W1080
Phone number 0421-218-62766
holzkeprotect me ?!ialb.uni-bremenprotect me ?!.de -
Principal investigatorNando Kaminski